Why approximate analysis

Exact analysis of a multi-storey, multi-bay frame is highly indeterminate. Approximate methods are still valuable to:

  • make preliminary sizing before computer analysis;
  • check computer output for gross errors;
  • understand how loads flow through a frame.

Each method introduces enough assumptions (usually locations of zero moment, or distribution of shear or axial force) to make the structure determinate.

Gravity (vertical) loads

Assumed points of inflexion

For a beam in a building frame under UDL:

  • If the ends were fixed, the points of contraflexure would be at from each end.
  • If the ends were pinned, the moment would be zero at the ends.
  • Actual beam ends are partly restrained, so a common assumption is inflexion points at about from each end, and zero axial force in the beam.

The beam then becomes a simply supported central segment of length on two cantilevers of :

Substitute frame method

To find beam moments at one floor, analyse only that floor's beams together with the columns immediately above and below, with the far ends of the columns fixed. Use moment distribution with two or three cycles. This is the approach suggested in codes for regular frames under gravity load, where pattern loading (live load on alternate or adjacent spans) is also considered for maximum span and support moments.

Two-cycle method

A shortened moment distribution — two cycles of balancing and carry-over — gives beam moments within engineering accuracy for regular frames.

Lateral loads (wind, earthquake)

Under horizontal loads at floor levels, columns and beams of a regular frame bend in double curvature, with points of inflexion near mid-height of columns and mid-span of beams.

Portal method

Suitable for low-rise frames (height smaller than width), where behaviour is dominated by shear (frame racking).

FormulaAssumptions of the portal method
  1. A point of inflexion at mid-height of every column.
  2. A point of inflexion at mid-span of every beam.
  3. The total horizontal shear in a storey is shared by the columns so that each interior column carries twice the shear of an exterior column (each bay acts like a separate portal sharing interior columns).

Steps

  1. Storey shear = sum of lateral loads above the mid-height of that storey. With bays (so interior columns): exterior column shear ; interior column shear .
  2. Column end moments shear (both ends, opposite sense).
  3. Beam end moments from joint equilibrium: at each joint, beam moments balance the column moments above and below.
  4. Beam shears (inflexion at mid-span).
  5. Column axial forces from beam shears; exterior columns carry the axial force, interior columns carry only the difference (zero for equal bays).

Cantilever method

Suitable for tall, slender frames (height large compared with width), which bend like a vertical cantilever.

FormulaAssumptions of the cantilever method
  1. Inflexion points at mid-height of columns and mid-span of beams (as in the portal method).
  2. The axial stress in each column is proportional to its distance from the centroid of all column areas in that storey (plane sections remain plane for the frame as a whole). With equal column areas, axial force is proportional to distance from the centroid.

Steps

  1. Locate the centroid of column areas at each storey.
  2. Take moments of lateral loads above a section through column inflexion points about the centroid; this equals where . Solve for column axial forces.
  3. Beam shears from vertical equilibrium of joints (difference of column axial forces).
  4. Beam end moments beam shear .
  5. Column shears and moments from joint equilibrium.

Factor method (outline)

The factor method (Wilbur) uses relative stiffnesses of beams and columns at each joint to estimate column and girder moments. It is more accurate than the portal and cantilever methods for frames with varying member sizes but more laborious.

Method Best suited to Key assumption
Portal Low, wide frames Interior columns take twice the shear of exterior columns
Cantilever Tall, narrow frames Column axial stress ∝ distance from centroid
Factor Irregular stiffness Moment shared by relative stiffness factors