← Building Materials & Construction

Stairs

Technical terms of stairs (step, tread, riser, nosing, going, rise, flight, landing, pitch, headroom, handrail, baluster, balustrade, newel, string, winders, waist); requirements of a good stair — location, width, riser and tread relations, number of steps, pitch, headroom, landings, handrails; types of stairs (straight, dog-legged, open well, quarter-turn, geometrical, bifurcated, spiral, helical) and materials (timber, stone, brick, steel, RCC, precast); structural behaviour of RCC stairs (waist slab and cantilever steps) and loads; planning and design of a staircase; ramps, lifts and escalators — with solved numericals.

📑 Contents (10 sections)

Last reviewed 16 Sept 2026 · 9 min read

Stairs

A stair is a series of steps arranged to connect different floors or levels. A staircase is the room or enclosure containing the stair.

Technical terms

Term Meaning
Step Portion of a stair comprising a tread and a riser
Tread Horizontal upper surface of a step on which the foot is placed
Riser Vertical portion between two consecutive treads
Rise Vertical height of a step (from top of one tread to the top of the next)
Going Horizontal distance between two consecutive risers (effective tread width); total going of a flight = sum of goings
Nosing Projecting edge of the tread beyond the face of the riser (rounded)
Scotia Moulding under the nosing to improve appearance
Flight An uninterrupted series of steps between two landings
Landing Level platform at the top/bottom of a flight or between flights — half-space landing (full width across two flights, turning 180°) and quarter-space landing (turning 90°)
Pitch (slope) Angle of inclination of the stair with the horizontal
Line of nosing Imaginary line through the nosings — parallel to the pitch
Headroom Minimum clear vertical distance from the line of nosing (or landing) to the ceiling/soffit above
Handrail Rail provided for support along the side of the flight
Baluster Vertical member supporting the handrail
Balustrade Row of balusters with the handrail
Newel post Heavy post at the start, end or turn of a flight supporting the handrail and strings
String (stringer) Inclined member supporting the ends of the steps — closed (housed) string (steps housed in it) and open (cut) string (profile cut to the steps)
Winders Tapering steps used to change direction (instead of a landing) — less safe
Flyers Ordinary parallel (rectangular) steps
Waist Thickness of the inclined slab of an RCC stair below the steps
Soffit Underside of the stair
Well Space between the outer strings of flights (open well stairs)

Requirements of a good stair

  1. Location — easily accessible from all rooms/areas, preferably near the entrance and centrally located; well lit and ventilated; fire escape considerations in large buildings.
  2. Width — adequate for traffic and furniture movement: commonly at least about 0.9–1.0 m in residences and 1.5 m or more in public buildings (as per bye-laws and fire codes).
  3. Rise and tread:
    • Rise commonly 150–190 mm (lower in public buildings, about 150 mm); tread commonly 250–300 mm.
    • Comfortable relations (empirical):
      • mm (commonly about 600 mm)
      • mm²
      • mm
    • All risers and treads in a flight must be uniform.
  4. Number of steps per flight — commonly not more than about 12–15 and not less than about 3.
  5. Pitch — generally between about 25° and 40° (about 30–35° comfortable).
  6. Headroom — at least about 2.1 m (2.0 m minimum in some codes) above the line of nosing.
  7. Landings — width not less than the width of the stair.
  8. Handrails — at a height of about 850–1000 mm above the nosing line; on both sides for wider stairs; balusters closely spaced for child safety.
  9. Winders avoided (or kept to a minimum); if used, placed at the bottom.
  10. Materials — strong, fire resistant, non-slippery treads (nosing strips).
  11. Balustrades on open sides.

Types of stairs

Type Arrangement Remarks
Straight stair All steps in one direction — single flight or flights with intermediate landings Simple; needs long narrow space; porches, narrow staircases, cellars
Dog-legged stair Two adjacent flights running in opposite directions with a half-space landing, no well between them (outer strings in the same vertical plane) Economical in space — most common in residential buildings
Open newel (open well) stair Flights with a well between them; turns at quarter-space landings (or half-turn with a well) Better appearance, more light, space for lifts in the well
Quarter-turn stair Direction changes by 90° with a quarter-space landing (or winders) Corners of halls
Half-turn stair Direction changes by 180° (dog-legged or open well) Common
Three-quarter-turn stair Direction changes by 270° Towers, compact spaces
Geometrical stair Curved flights (circular/elliptical) with a continuous string and handrail, no newel posts Architectural, elegant
Bifurcated stair A wide flight splits into two narrower flights at a landing, going in opposite directions Public buildings, entrance halls
Spiral stair Steps radiating around a central post (newel), winding as winders Very limited space, emergency and service stairs, towers (often steel or precast)
Helical stair Curved about a vertical axis without a central column (circular in plan) Architectural RCC/steel stairs
Ladders Steep access Lofts, service access

Materials

Material Features
Timber Light, easy to build; poor fire resistance — residential interiors, lofts
Stone Durable, strong — steps cantilevered from walls or supported on strings; heavy
Brick Solid steps built on brickwork — low buildings, external steps
Steel Strings with pressed/chequered plate or grating treads — industrial buildings, fire escapes, spiral stairs
RCC Most common — strong, fire resistant, durable, any shape; cast in situ or precast
Precast concrete Precast steps or entire flights — speed
Glass, aluminium, composite Architectural stairs

RCC stairs — structural behaviour

Type Behaviour
Stairs spanning longitudinally (waist slab type) The inclined waist slab spans along the flight between supports (landing beams, walls or floor slabs); main reinforcement along the slope in the waist; steps are formed over the slab
Stairs spanning transversely Each step spans across the width between side walls/stringer beams, or cantilevers from a wall or a central beam (cantilever steps)
Folded plate (slabless) stairs Treads and risers act together as a folded plate without a separate waist
Stairs with stringer beams Inclined beams on one or both sides carry the steps

Loads: self-weight of waist and steps, floor finish, and live load as per IS 875 (Part 2) — commonly about 3 kN/m² for residential buildings and higher (about 4–5 kN/m²) for public buildings and areas subject to crowding. IS 456 gives guidance on effective span and load distribution for stairs.

This chapter is in the syllabus of

Open an exam to see where this chapter sits in its syllabus, and to practise it.

✅ Free — no sign-up needed

How ready are you for Building Materials & Construction?

Ten questions from the real syllabus, about five minutes. You will see your score and which subject is holding you back — before you create any account.