Part 1 of 2
Air Pollution & Its Control
Last reviewed 16 Sept 2026 · Facts as of 16 Sept 2026 · 12 min read
Air and air pollution
Clean dry air is about 78% nitrogen, 21% oxygen, 0.93% argon, about 0.04% carbon dioxide and traces of other gases, plus variable water vapour.
Air pollution is the presence in the atmosphere of substances in concentrations and durations that cause harm to human health, living organisms, materials or the environment. In India it is legally defined under the Air (Prevention and Control of Pollution) Act, 1981.
Sources and classification
| Basis | Classes |
|---|---|
| Origin | Natural (volcanoes, dust storms, forest fires, pollen, sea spray) and anthropogenic (industries, vehicles, power plants, domestic fuel, burning of waste and crop residue, construction dust) |
| Source geometry | Point (stacks), line (highways), area (cities, industrial estates) |
| Mobility | Stationary (industries, power plants) and mobile (vehicles, aircraft, ships) |
| Formation | Primary pollutants — emitted directly (SO₂, NOx, CO, particulates, hydrocarbons); secondary pollutants — formed in the atmosphere by reactions (ozone, PAN — peroxyacetyl nitrate, sulphuric acid mist, secondary nitrate and sulphate aerosols) |
| Physical state | Particulate (dust, fumes, smoke, mist, fog, fly ash, aerosols) and gaseous |
Particulate matter terms: dust (solid particles from mechanical processes), fumes (fine solids from condensation of vapours, e.g. metal fumes), smoke (fine particles from incomplete combustion), mist (liquid droplets), fly ash (fine ash from combustion), PM₁₀ (aerodynamic diameter ≤ 10 µm — inhalable) and PM₂.₅ (≤ 2.5 µm — fine, penetrates deep into the lungs).
Major pollutants and their effects
| Pollutant | Main sources | Effects |
|---|---|---|
| Particulate matter (PM₁₀, PM₂.₅) | Vehicles, road and construction dust, combustion, industries, biomass burning | Respiratory and cardiovascular diseases, reduced visibility, soiling |
| Sulphur dioxide (SO₂) | Burning of coal and oil (power plants, smelters) | Respiratory irritation; acid rain; damage to vegetation (chlorosis and necrosis of leaves); corrosion of materials |
| Oxides of nitrogen (NOx) | High-temperature combustion — vehicles, power plants | Respiratory effects; acid rain; precursor of photochemical smog and ozone |
| Carbon monoxide (CO) | Incomplete combustion — vehicles, stoves | Combines with haemoglobin (about 200 times more strongly than oxygen) forming carboxyhaemoglobin — reduces oxygen delivery; headache, dizziness, death at high levels |
| Ozone (O₃) (ground-level, secondary) | NOx + VOCs + sunlight | Eye and lung irritation, crop damage, rubber cracking |
| Hydrocarbons / VOCs (e.g. benzene) | Vehicles, solvents, fuel evaporation | Smog precursors; benzene is carcinogenic |
| Lead | Earlier from leaded petrol; smelters, batteries | Neurotoxic — especially harmful to children |
| Ammonia | Agriculture, fertiliser plants | Secondary particle formation, irritation |
| Fluorides | Aluminium smelters, phosphate fertiliser plants | Fluorosis in cattle, damage to vegetation |
| Benzo(a)pyrene, arsenic, nickel | Combustion, industries | Carcinogenic |
Indoor air pollution — from cooking with biomass and kerosene, tobacco smoke, radon, formaldehyde and VOCs — is a major health risk, especially for women and children in rural households.
Bhopal gas tragedy (1984) — leak of methyl isocyanate (MIC) from a pesticide plant; one of the worst industrial disasters, which led to stronger environmental and liability laws in India.
Global and regional issues
Acid rain
SO₂ and NOx oxidise to sulphuric and nitric acids that fall with rain (pH below about 5.6). Effects: acidification of lakes and fish kills, forest damage, leaching of soil nutrients, corrosion of buildings and monuments (e.g. marble cancer concerns for the Taj Mahal).
Greenhouse effect and global warming
Greenhouse gases — CO₂, CH₄, N₂O, CFCs/HFCs, water vapour, tropospheric ozone — absorb outgoing infrared radiation and warm the earth. Increasing concentrations cause global warming, sea-level rise, changing rainfall patterns and extreme events. Gases differ in global warming potential (GWP) relative to CO₂.
Ozone layer depletion
Stratospheric ozone absorbs harmful UV-B radiation. CFCs, halons, carbon tetrachloride, methyl chloroform release chlorine and bromine that destroy ozone (the Antarctic ozone hole). Controlled under the Montreal Protocol (1987); the Kigali Amendment (2016) phases down HFCs (potent greenhouse gases). Ozone thickness is measured in Dobson units.
Smog
| Classical (London / sulphurous) smog | Photochemical (Los Angeles) smog |
|---|---|
| Smoke + fog + SO₂ | NOx + hydrocarbons + sunlight → O₃, PAN, aldehydes |
| Cool, humid winter conditions; reducing | Warm, sunny conditions; oxidising |
| Respiratory distress (London, 1952) | Eye irritation, respiratory effects, crop damage |
National Ambient Air Quality Standards (NAAQS, 2009)
Notified by CPCB for 12 pollutants (values for industrial, residential, rural and other areas):
| Pollutant | Annual average | 24-hour average |
|---|---|---|
| SO₂ (µg/m³) | 50 | 80 |
| NO₂ (µg/m³) | 40 | 80 |
| PM₁₀ (µg/m³) | 60 | 100 |
| PM₂.₅ (µg/m³) | 40 | 60 |
| Ozone (µg/m³) | — | 100 (8-hour), 180 (1-hour) |
| Lead (µg/m³) | 0.5 | 1.0 |
| CO (mg/m³) | — | 2 (8-hour), 4 (1-hour) |
| Ammonia (µg/m³) | 100 | 400 |
| Benzene (µg/m³) | 5 | — |
| Benzo(a)pyrene (ng/m³) | 1 | — |
| Arsenic (ng/m³) | 6 | — |
| Nickel (ng/m³) | 20 | — |
(Stricter annual limits apply to SO₂ and NO₂ in ecologically sensitive areas.)
Air Quality Index (AQI)
India's National AQI (launched 2014) combines up to eight pollutants (PM₁₀, PM₂.₅, NO₂, SO₂, CO, O₃, NH₃, Pb) into one number; the overall AQI is the highest sub-index.
| AQI | Category |
|---|---|
| 0–50 | Good |
| 51–100 | Satisfactory |
| 101–200 | Moderately polluted |
| 201–300 | Poor |
| 301–400 | Very poor |
| 401–500 | Severe |
National Clean Air Programme (NCAP) — launched in January 2019 to reduce particulate pollution in non-attainment cities through city action plans (targets have been revised over time; check current MoEFCC documents).
Air pollution meteorology
Lapse rates and stability
- Environmental lapse rate (ELR) — actual rate of temperature decrease with height.
- Dry adiabatic lapse rate (DALR) — cooling of a rising dry air parcel ≈ 9.8 °C per km (about 1 °C per 100 m).
- Wet adiabatic lapse rate — lower (about 6 °C per km) due to latent heat release.
| Condition | Atmosphere |
|---|---|
| ELR > DALR (super-adiabatic) | Unstable — strong vertical mixing (good dispersion) |
| ELR = DALR | Neutral |
| ELR < DALR (sub-adiabatic) | Stable — little vertical mixing |
| Temperature increases with height (negative lapse rate) | Inversion — very stable; traps pollutants |
Inversions: radiation inversion (clear calm nights — ground cools rapidly; common in winter mornings), subsidence inversion (sinking air in high-pressure systems; persistent, at elevation).
Maximum mixing depth (height) — the height up to which convective mixing occurs; low mixing heights (winter nights and mornings) cause high pollution levels.
Plume behaviour
| Plume | Atmospheric condition | Remarks |
|---|---|---|
| Looping | Super-adiabatic (highly unstable) | Large eddies bring the plume to the ground intermittently — high short-term ground concentrations near the stack |
| Coning | Neutral or slightly stable | Cone-shaped spread; reaches ground farther away |
| Fanning | Strong inversion/stable (at stack height) | Spreads horizontally, little vertical spread; low ground concentration unless terrain rises |
| Lofting | Inversion below the stack, unstable above | Pollutants dispersed upwards — most favourable |
| Fumigation | Inversion above the stack, unstable below | Pollutants pushed down to the ground — most unfavourable (morning break-up of a night inversion) |
| Trapping | Inversions both above and below the stack | Plume confined between layers |
Dispersion and stack height
= emission rate; = wind speed at stack height; , = dispersion coefficients (depend on distance and stability class); = effective stack height (physical height + plume rise).
Maximum ground-level concentration on the centreline occurs approximately where .
Plume rise increases with exit velocity and gas temperature (buoyancy) — e.g. Holland's and Briggs' formulas.
- Based on SO₂ emission: — in kg/h of SO₂
- Based on particulate emission: — in tonnes/h of particulates
- The larger value is adopted, subject to a minimum stack height (commonly 30 m).
Quick check · 5 questions · 3 minutes
Padh liya? Ab dekho kitna yaad raha.
Five exam-level questions from Environmental Engineering. No timer, no payment.
Control of air pollution
At the source
Use of cleaner fuels (low-sulphur fuels, natural gas, washed coal), process modification, improved combustion, energy efficiency and renewable energy, maintenance, relocation and zoning of industries, green belts.
Particulate control devices
| Device | Principle | Particle size | Efficiency / remarks |
|---|---|---|---|
| Gravity settling chamber | Particles settle under gravity in a large chamber with low velocity | Coarse (above about 50 µm) | Low; used as pre-cleaner |
| Cyclone separator | Centrifugal force throws particles to the walls | Medium (above about 5–10 µm) | Moderate; cheap, no moving parts; multiclones for higher efficiency |
| Fabric filter (baghouse) | Gas passes through fabric bags; dust cake filters | Very fine (sub-micron) | Very high (> 99%); temperature and moisture limits; bag cleaning by shaking or pulse jet |
| Electrostatic precipitator (ESP) | Particles charged by corona discharge and collected on plates | Very fine (about 0.1 µm upward) | Very high (> 99%); low pressure drop; high capital cost; widely used in thermal power plants and cement plants |
| Wet scrubbers (spray tower, venturi scrubber) | Particles captured by liquid droplets | Fine (venturi scrubber) | High; also remove soluble gases; produce wastewater |
Settling chamber (laminar): (limited to 1)
ESP (Deutsch–Anderson equation):
= drift (migration) velocity; = collecting plate area; = gas flow rate.
Gaseous pollutant control
| Method | Application |
|---|---|
| Absorption (scrubbing in packed or spray towers) | Soluble gases; flue gas desulphurisation (FGD) — limestone/lime slurry absorbs SO₂ forming gypsum |
| Adsorption (activated carbon, silica gel, zeolites) | VOCs, odours, solvent recovery |
| Combustion (flares, thermal and catalytic incinerators) | Combustible gases and VOCs |
| Catalytic reduction — SCR/SNCR with ammonia or urea | NOx from power plants |
| Low-NOx burners, flue gas recirculation | Reduce NOx formation |
| Condensation | Vapours with high boiling points |
Vehicular pollution control
- Three-way catalytic converters (convert CO, HC and NOx to CO₂, H₂O and N₂) — require unleaded fuel.
- Emission norms — India moved directly from Bharat Stage IV to Bharat Stage VI nationwide in April 2020 (with low-sulphur fuel).
- Cleaner fuels (CNG, LPG), electric vehicles, diesel particulate filters, pollution under control (PUC) checks, public transport, traffic management, restrictions during severe episodes (e.g. Graded Response Action Plan in Delhi–NCR).
Sampling and monitoring
- High-volume sampler — suspended particulate matter on a glass-fibre filter.
- Respirable dust sampler — PM₁₀ with a cyclone separator; PM₂.₅ samplers with impactors.
- Impingers/bubblers with absorbing solutions for SO₂ (improved West–Gaeke method) and NO₂ (Jacobs–Hochheiser method).
- Continuous ambient air quality monitoring stations (CAAQMS) with automatic analysers; stack monitoring (isokinetic sampling).
= molecular weight (g/mol); 24.45 L = molar volume at 25 °C.
Worked examples
Convert 0.02 ppm of SO₂ to µg/m³ at 25 °C.
Solution.
An ESP has a plate area of 5000 m², drift velocity 0.1 m/s and treats 100 m³/s of flue gas. Find its efficiency.
Solution.
A settling chamber 10 m long and 5 m wide handles 5 m³/s. Find the collection efficiency for particles with a terminal velocity of 0.05 m/s.
Solution. (50%)
A boiler emits 1000 kg/h of SO₂. Find the minimum stack height by the SO₂ criterion.
Solution.
Temperature falls from 30 °C at the ground to 28 °C at 400 m. Classify the atmosphere.
Solution. ELR °C/km < DALR (9.8 °C/km) → sub-adiabatic — stable.
Frequently tested points
- Primary: SO₂, NOx, CO, PM; secondary: O₃, PAN, acid mist.
- PM₂.₅ penetrates deepest; CO forms carboxyhaemoglobin; SO₂ causes chlorosis and acid rain.
- Acid rain pH < 5.6; CFCs deplete stratospheric ozone (Montreal Protocol 1987; Kigali 2016 for HFCs).
- London smog: SO₂ + smoke (reducing); photochemical smog: NOx + HC + sunlight (oxidising).
- NAAQS 2009: 12 pollutants; PM₁₀ 60/100, PM₂.₅ 40/60, SO₂ 50/80, NO₂ 40/80 µg/m³.
- AQI categories: good, satisfactory, moderately polluted, poor, very poor, severe.
- DALR ≈ 9.8 °C/km; ELR > DALR unstable; inversion very stable.
- Looping (unstable), coning (neutral), fanning (stable), lofting (best), fumigation (worst).
- Stack height (SO₂, kg/h); (PM, t/h).
- Settling chamber > 50 µm; cyclone > 5–10 µm; bag filter and ESP for fine particles; Deutsch–Anderson .
- FGD with limestone for SO₂; SCR for NOx; activated carbon for VOCs; three-way catalytic converters.
- BS-IV to BS-VI in April 2020.
- Calling ozone a primary pollutant in the lower atmosphere.
- Saying fumigation is favourable (it brings the plume to the ground).
- Using a cyclone to capture sub-micron particles efficiently.
- Air pollutants come from natural and human sources and are primary or secondary, particulate or gaseous.
- They harm health, vegetation, materials and visibility, and cause acid rain, global warming, ozone depletion and smog.
- NAAQS and the AQI define and communicate air quality in India.
- Lapse rates, stability, inversions and mixing height control dispersion and plume shapes; stack height is set by emission-based formulas.
- Particulates are controlled by settling chambers, cyclones, bag filters, ESPs and scrubbers; gases by absorption, adsorption, combustion and catalytic methods; vehicles by cleaner fuels, BS-VI norms and catalytic converters.