Treatment flow sheet
A conventional surface water treatment plant:
Intake and screens → (plain sedimentation for very turbid water) → aeration (if needed) → rapid mixing with coagulant → flocculation → sedimentation (clarification) → rapid sand filtration → disinfection → clear water reservoir → distribution
Groundwater often needs only aeration, iron/manganese removal and disinfection; hard or fluoride-rich water needs special treatment.
| Unit | Main impurity removed |
|---|---|
| Screening | Large floating matter |
| Aeration | Dissolved gases (CO₂, H₂S), tastes and odours; oxidises iron and manganese |
| Plain sedimentation | Settleable suspended solids |
| Coagulation–flocculation–sedimentation | Colloidal turbidity and colour |
| Filtration | Remaining fine flocs, turbidity, some bacteria |
| Disinfection | Pathogens |
| Softening | Hardness |
Screening
- Coarse screens (bar racks) at the intake to exclude floating debris, and fine screens or micro-strainers for smaller matter and algae.
- Cleaned manually or mechanically; velocity through screens kept low.
Aeration
Brings water into intimate contact with air:
- Removes CO₂ (reduces corrosiveness), H₂S and volatile tastes and odours.
- Adds oxygen — oxidises dissolved iron and manganese to insoluble forms that can be settled and filtered.
Types: spray aerators (nozzles), cascade aerators (water flows down steps), multiple tray aerators (perforated trays with coke/gravel), diffused air aerators (compressed air bubbled through water), mechanical aerators.
Sedimentation
Types of settling
| Type | Description | Example |
|---|---|---|
| Type I — discrete settling | Particles settle individually without interaction at constant velocity | Plain sedimentation of sand/silt, grit chambers |
| Type II — flocculent settling | Particles coalesce, grow and settle faster | Coagulated water, primary sewage settling |
| Type III — zone (hindered) settling | High concentration; particles settle as a mass with a distinct interface | Secondary clarifiers (activated sludge) |
| Type IV — compression | Particles form a structure compressed by the weight above | Sludge thickeners, bottom of clarifiers |
Stokes' law (laminar, , small particles):
Ideal settling basin (Camp–Hazen):
- Surface overflow rate (SOR) (m³/m²/day) — equal to the settling velocity of the smallest particle removed completely.
- Particles with are removed 100%; particles with are removed in the fraction .
- Removal depends on surface area, not on depth (in theory).
Detention time ; horizontal velocity (kept below the scour velocity); weir loading = ÷ weir length.
Typical design values (clarifiers after coagulation, CPHEEO guidance): detention time about 2–2.5 h; surface loading about 30–40 m³/m²/day; weir loading not exceeding about 300 m³/m/day. Plain sedimentation tanks without coagulant need longer detention.
Types of tanks
- Horizontal-flow rectangular tanks — long, narrow; inlet and outlet baffles; sludge scraped to a hopper.
- Circular radial-flow tanks — central feed, peripheral weir; rotating scraper.
- Upflow (hopper-bottom) tanks and sludge blanket clarifiers.
- Tube (lamella) settlers — inclined tubes or plates reduce the settling distance, greatly increasing capacity in a small area.
Quick check · 5 questions · 3 minutes
Padh liya? Ab dekho kitna yaad raha.
Five exam-level questions from Environmental Engineering. No timer, no payment.
Coagulation and flocculation
Colloidal particles (clay, colour, bacteria) are negatively charged and repel each other, so they do not settle. Coagulation destabilises them; flocculation gently brings them together into large, settleable flocs.
Mechanisms
- Charge neutralisation — positively charged hydrolysis products of coagulants neutralise particle charges.
- Double-layer compression.
- Sweep (enmeshment) coagulation — particles trapped in precipitating metal hydroxide flocs (dominant at usual alum doses).
- Inter-particle bridging — by long-chain polymers.
Coagulants
| Coagulant | Features |
|---|---|
| Alum — aluminium sulphate | Most common; cheap; best pH about 6.5–8.5; consumes alkalinity |
| Ferrous sulphate (copperas) + lime | For high pH waters; used where lime is added anyway |
| Chlorinated copperas (ferric sulphate + ferric chloride) | Effective over a wide pH range; removes colour |
| Ferric chloride / ferric sulphate | Wide pH range, dense flocs; corrosive |
| Sodium aluminate | For waters low in alkalinity; also used in softening |
| Poly-aluminium chloride (PAC) | Pre-hydrolysed; effective at low doses and low temperatures; less alkalinity consumed |
Coagulant aids: activated silica, bentonite clay, polyelectrolytes (cationic, anionic, non-ionic polymers), lime or soda ash (to supply alkalinity or adjust pH).
Alum reaction with natural alkalinity:
1 mg/L of commercial alum (, molecular weight ≈ 666) consumes about 0.45 mg/L alkalinity as CaCO₃.
Jar test — samples dosed with different coagulant amounts are rapidly mixed, flocculated and settled in a gang stirrer; the dose giving the best clarity at least cost is the optimum dose.
Mixing and flocculation
= power input (W); = dynamic viscosity; = volume of the tank.
Paddle flocculator: , where = relative velocity of paddles with respect to water (≈ 0.75 × paddle tip velocity).
The dimensionless product measures the opportunity for particle collisions.
- Rapid (flash) mixing — intense agitation for a few seconds to about a minute (high ) to disperse coagulant uniformly: mechanical flash mixers, hydraulic jumps, baffles, in-line mixers.
- Flocculation (slow mixing) — gentle agitation for about 10–40 minutes with low (commonly about 10–75 s⁻¹) so flocs grow without breaking: paddle flocculators, baffled channels.
- Clariflocculator — a circular unit combining a central flocculation zone with an outer clarifier; widely used in India.